Product description
AC power supply analog supply is an economical variable frequency power supply, manufactured by well-known brand components in the industry, providing pure and reliable sine wave power output, low harmonic distortion, high stability frequency and voltage regulation rate, which can simulate different countries in the world. Output characteristics of voltage and frequency. The frequency conversion power supply is mainly for the economical use requirements of small and medium-sized electronics and electrical appliance manufacturing enterprises, and meets the application of product testing, life, over-high voltage/over-low voltage simulation test in design and development, production line testing and quality assurance.
Features
1. Input voltage: 220V/380V; output voltage: 0-300VAC/0-520VAC.
2. Input frequency: 50Hz, 60Hz; output frequency: 40-120Hz, 40-499.9Hz can be ordered separately.
3, voltage, frequency, current, power meter using 4-digit LED display, simple, easy to read, high resolution.
4, voltage (V), frequency (Hz), current (A), power (W) 4 window simultaneous measurement, display, no need to switch.
5, no radiation interference, containing harmonic components, and special treatment, no interference.
6, pure, stable sine wave output.
7, large capacity, high efficiency; quiet device, high reliability.
8, to provide the world's standard voltage, frequency, simulation test a variety of electrical products.
9, the overload capacity is strong, the instantaneous current can withstand 3 times the rated current.
10. With over current, over temperature, short circuit, instantaneous power failure protection and warning device.
11. Suitable for resistive, capacitive, inductive and other non-linear loads.
Technical Parameters
Production method
|
IGBT/PWM pulse width modulation method
|
Model
|
HK-3110
|
HK-3115
|
HK-3120
|
HK-3130
|
Capacity
|
10KVA
|
15KVA
|
20KVA
|
30KVA
|
Input
|
Phase
|
Three phase
|
Voltage
|
3-phase 4-wire + G: 380V ± 10%
|
Frequency
|
50Hz/60Hz
|
Output
|
Voltage (single phase)
|
Low: 0-150V
|
High grade: 0-300V
|
Frequency
|
40.0Hz-120Hz
|
Current
|
Low gear
|
L:83.3A
|
L:125A
|
L:166.6A
|
L:250A
|
High grade
|
H:41.6A
|
H:62.5A
|
H:83.3A
|
H:125A
|
Load stability rate
|
≤1%
|
Frequency stability
|
≤±0.01%
|
Harmonic distortion
|
Sine wave, ≤2%
|
Crest factor ratio
|
3:1
|
Machine efficiency
|
≥85%
|
Reaction time
|
100% loaded or unloaded≤2ms
|
Display
|
Frequency table
|
4-digit, digital frequency meter / resolution 0.1Hz
|
Voltage
|
4-digit, digital voltmeter / resolution 0.1V
|
Current
|
4-digit, digital ammeter / resolution 0.1A
|
Watt table
|
4-digit, digital wattmeter / resolution 0.1W
|
Protective device
|
Protection alarm device with overload over temperature, short circuit, instantaneous power failure, FUSE fuse
|
Working environment
|
Temperature
|
0-40deg.℃
|
Humidity
|
0-90%(Non-condensing state)
|
Chassis size(cm)
|
68*50*97cm
|
77*58*114cm
|
Weight
|
123KG
|
150KG
|
174KG
|
200KG
|
Production method
|
IGBT/PWM pulse width modulation method
|
Model
|
HK-33100
|
HK-33120
|
HK-33150
|
HK-33200
|
HK-33300
|
Capacity
|
100KVA
|
120KVA
|
150KVA
|
200KVA
|
300KVA
|
Special specifications
|
Input
|
Phase
|
Three phase
|
Voltage
|
3-phase 4-wire + G: 380V ± 10%
|
Frequency
|
50Hz/60Hz
|
Output
|
Voltage (single phase)
|
0-150V phase voltage 0-150V / line voltage 0-260V (low level)
|
0-300V phase voltage 0-300V / line voltage 0-520V (high grade)
|
Frequency
|
40Hz-120Hz
|
Current
|
Low gear
|
L:277.7A
|
L:33.3A
|
L:416.6A
|
L:555.5A
|
L:833.3A
|
High grade
|
H:138.8A
|
H:166.6A
|
H:208.3A
|
H:277.7A
|
H:416.6A
|
Load stability rate
|
≤1%
|
Frequency stability
|
≤±0.01%
|
Harmonic distortion
|
Sine wave,≤2%
|
Crest factor ratio
|
3:1
|
Machine efficiency
|
≥85%
|
Reaction time
|
100% loading or unloading ≤ 2ms
|
Display
|
Frequency table
|
4-digit, digital frequency meter / resolution 0.1Hz
|
Voltage
|
4-digit, digital voltmeter / resolution 0.1V
|
Current
|
4-digit, digital ammeter / resolution 0.1A
|
Watt table
|
4-digit, digital wattmeter / resolution 0.1W
|
Protective device
|
Protection alarm device with overload over temperature, short circuit, instantaneous power failure, FUSE fuse
|
Working environment
|
Temperature
|
0-40deg.℃
|
Humidity
|
0-90%(Non-condensing state)
|
Chassis size(cm)
|
150*86*143cm
|
Weight
|
720KG
|
900KG
|
1100KG
|
1200KG
|
1500KG
|